Ultrasonic sensors - Long type M18

Share on facebook
Share on twitter
Share on linkedin
Share on pinterest
Share on whatsapp
Share on email

Roll over image to zoom in

Often Purchased With
Ultrasonic sensors - Long type M18
This item: Ultrasonic sensors - Long type M18

  • Very large detection range
  • Intuitive setting of the detection range via pushbutton or IO-Link
  • Clearly visible LED for indicating switching status and echo
  • With programmable switching output and scalable analogue output
  • Non-contact detection independent of colour, transparency or surface characteristics of the object

Request a quote

Description

Product characteristics
Electrical design PNP
Output function normally open / normally closed; (parameterisable + 1x current output)
Sensing range [mm] 200…2200; (Target: 200 x 200 mm)
Communication interface IO-Link
Housing threaded type
Dimensions [mm] Ultrasonic sensors – Long type M18 M18 x 1 / L = 97.5
Electrical data
Operating voltage [V] 10…30 DC; (“supply class 2” to cULus)
Current consumption [mA] 55
Protection class III
Reverse polarity protection yes
Power-on delay time [s] < 0.3
Converter frequency [kHz] 200
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 1; Number of analogue outputs: 1
Outputs
Total number of outputs 2
Electrical design PNP
Number of digital outputs 1
Output function normally open / normally closed; (parameterisable + 1x current output)
Max. voltage drop switching output DC [V] 2.2
Permanent current rating of switching output DC [mA] 100
Switching frequency DC [Hz] 2
Number of analogue outputs 1
Analogue current output [mA] 4…20
Max. load [Ω] 500
Short-circuit protection yes
Overload protection yes
Resolution of analogue output < 3 mm
Detection zone
Sensing range [mm] 200…2200; (Target: 200 x 200 mm)
Blind zone [mm] 200
Angle of aperture cylindrical [°] 14; (±2)
Max. deviation from the 90° angle sensor/object [°] ± 4
Accuracy / deviations
Temperature compensation yes
Hysteresis [%] < 2
Switch point drift [%] -2…2
Linearity error of analogue output [%] <3
Notes on the accuracy / deviation The indicated values are reached after a warm-up time of min. 20 minutes
Repeatability 1 %
Response times
Response time [ms] < 400; (analogue output)
Software / programming
Parameter setting options hysteresis / window; second switch point; Switch-on and switch-off delay; switch-on operations; Teach function; light-on/dark-on mode
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
Profiles Smart Sensor: Device Identification; Multi-channel, two setpoint switching sensor, type 0 Generic Profiled Sensor; Process Data Variable; Device Diagnosis; Teach Channel
SIO mode yes
Required master port type A
Min. process cycle time [ms] 3.2
IO-Link process data (cyclical)
function bit length
process value 16
device status 4
binary switching information 2
IO-Link functions (acyclical) application specific tag; operating hours counter
Supported DeviceIDs
Type of operation IO-Link device ID
Default 704 d / 00 02 C0 h
Note
For further information please see the IODD PDF file under “Downloads”
Operating conditions
Ambient temperature [°C] -20…70
Storage temperature [°C] -30…80
Protection IP 67
Tests / approvals
EMC
EN 61000-4-2 ESD 4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated 3 V/m
EN 61000-4-4 Burst 2 kV
EN 61000-4-6 HF conducted 3 V
EN 55011 Class A
Vibration resistance
EN 60068-2-6 Fc (10-55) Hz 1 mm amplitude, oscillation period 5 min., 30 min. per axis at resonance or 55 Hz
Shock resistance
EN 60068-2-27 Ea 30 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes
MTTF [years] 142
UL approval
Ta -20…70 °C
voltage supply Class 2
File number UL E174191
Mechanical data
Weight [g] 102
Housing threaded type
Dimensions [mm] M18 x 1 / L = 97.5
Thread designation M18 x 1
Materials stainless steel (1.4404 / 316L); PA; epoxy glass ceramics
Tightening torque [Nm] 50
Displays / operating elements
Display
switching status 2 x LED, yellow
echo 1 x LED, green
Teach function yes
Accessories
Accessories (supplied)
lock nuts: 2, stainless steel
Remarks
Remarks
operating voltage “supply class 2” according to cULus
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12
Diagrams and graphs

1: distance
2: Detection zone
3: switch-on/switch-off graph
4: Target 200 x 200 mm
5: 50% of the target in the detection zone
6: switch point

Fast Shipping

Stocked Inventory

Competitive Pricing

High-Quality Products

Subscribe to our newsletter and recevie a $50 voucher!

Get updates and learn from the best

Ultrasonic sensors – Long type M18 60d4c19bcd098

Ultrasonic sensors – Long type M18 60d4c19bcd0b0