Temperature Sensors - Self-Monitoring Transmitters

Thanks to the calibration check technology, the TCC permanently checks its own drift behaviour. The sensor compares the temperature value to the simultaneously measured reference value. If the deviation is outside the tolerance range, which can be set between 0.5 and 3 K, the TCC provides an optical signal and sends a message to the central controller via IO-Link and the diagnostic output. The same applies to cases of serious malfunctions.

Thanks to their hygienic design, high protection rating and integrated process connection, the sensors are particularly suited for applications in the food, beverage and pharmaceutical industries.

The sensors are available with different probe lengths and process connections. They can be configured via IO-Link, e.g. using a USB interface. The LR DEVICE software is used to visualise, transfer and archive parameter sets

  • Integrated drift monitoring and diagnostic function
  • Free factory calibration certificate available
  • High process reliability and plant uptime due to self-monitoring
  • Short response time
  • High precision of 0.2 K
Share on facebook
Share on twitter
Share on linkedin
Share on pinterest
Share on whatsapp
Share on email

Description

Product Temperature Sensors Measuring range temperature Factory setting Output function Analogue output Process connection
TCC281 -25…160 °C / -13…320 °F -10…150 °C / 14…302 °F normally open; (diagnostic signal); analogue 4…20 mA diameter Ø 6 mm
TCC201 -25…160 °C / -13…320 °F -10…150 °C / 14…302 °F normally open; (diagnostic signal); analogue 4…20 mA diameter Ø 6 mm
TCC231 -25…160 °C / -13…320 °F -10…150 °C / 14…302 °F normally open; (diagnostic signal); analogue 4…20 mA diameter Ø 6 mm
TCC911 -25…160 °C / -13…320 °F -10…150 °C / 14…302 °F normally open; (diagnostic signal); analogue 4…20 mA Clamp DN50 (2″)
TCC241 -25…160 °C / -13…320 °F -10…150 °C / 14…302 °F normally open; (diagnostic signal); analogue 4…20 mA diameter Ø 6 mm
TCC811 -25…160 °C / -13…320 °F -10…150 °C / 14…302 °F normally open; (diagnostic signal); analogue 4…20 mA Clamp DN25…DN40 (1…1,5″)
TCC931 -25…160 °C / -13…320 °F -10…150 °C / 14…302 °F normally open; (diagnostic signal); analogue 4…20 mA Clamp DN50 (2″)
TCC261 -25…160 °C / -13…320 °F -10…150 °C / 14…302 °F normally open; (diagnostic signal); analogue 4…20 mA diameter Ø 6 mm
TCC831 -25…160 °C / -13…320 °F -10…150 °C / 14…302 °F normally open; (diagnostic signal); analogue 4…20 mA Clamp DN25…DN40 (1…1,5″)
TCC291 -25…160 °C / -13…320 °F -10…150 °C / 14…302 °F normally open; (diagnostic signal); analogue 4…20 mA diameter Ø 6 mm
TCC511 -25…160 °C / -13…320 °F -10…150 °C / 14…302 °F normally open; (diagnostic signal); analogue 4…20 mA G 1/2 sealing cone
TCC531 -25…160 °C / -13…320 °F -10…150 °C / 14…302 °F normally open; (diagnostic signal); analogue 4…20 mA G 1/2 sealing cone
TCC541 -25…160 °C / -13…320 °F -10…150 °C / 14…302 °F normally open; (diagnostic signal); analogue 4…20 mA G 1/2 sealing cone
TCC501 -25…160 °C / -13…320 °F -10…150 °C / 14…302 °F normally open; (diagnostic signal); analogue 4…20 mA G 1/2 sealing cone

REQUEST A QUOTE!

Related products

Fast Shipping

Stocked Inventory

Competitive Pricing

High-Quality Products

Subscribe to our newsletter and recevie a $50 voucher!

Get updates and learn from the best

Temperature Sensors – Self-Monitoring Transmitters 6144c53903dde

Temperature Sensors – Self-Monitoring Transmitters 6144c53903df7